Dimensions

The dimensions for the Montana Flume are based upon those of the Parshall Flume from which it's derived. 

The dimensions and tolerances of Parshall Flumes have been standardized in several national / international standards and authoritative publications:

The Montana Flume is defined in:

It's critically important to note that although Montana Flumes share a standard layout, they are NOT scale models of each other – they are empirical devices for which flow rate investigations were conducted.

The use of non-standard flume sizes is HIGHLY discouraged, and the dimensions and flow accuracies of such devices should be considered suspect.

ASTM D1941 requires that Parshall (Montana) Flumes have dimensions within +/-2% of nominal, while JIS B7553 requires tolerance of +/- 1-1.5% depending upon flume size.  

Parshall (Montana) Flumes with dimensions outside of these ranges should be considered non-conforming and should be either replaced for field rates.

MONTANA FLUME MASTER DIMENSIONS

LOCATIONS IN ATLANTA, GA & BOISE, ID